Skip to main content
User Image

Shahid Parvez

Associate Professor

Faculty

Engineering
Building 3, 2nd Floor, 2C25
publication
Journal Article
2026

A Comparative Analysis of the Weld Pools Created with DC Single-, DC Double-, and PC Double-Electrode Configurations in Autogenous GTAW

Three different Gas Tungsten Arc Welding methods—DC single electrode, DC double electrode, and PC double electrode—were analyzed using SS304 steel as the base material. Numerical models were developed to simulate the arc plasmas and calculate heat flux, current density, and wall shear stress on the surface of the workpiece. These data were used as input to simulate the weld pools across all three configurations. Experimental validation showed a good agreement with the numerical results. In the double-electrode setup, electromagnetic interaction caused the arcs to deflect, resulting in an 8% reduction in the maximum heat flux and a 4% decrease in the maximum current density. Marangoni stress had a notable effect on the weld pool shape, creating a Jmmp 10 00032 i001-shaped pool with the stationary single-electrode setup, whereas the double-electrode setup produced a Jmmp 10 00032 i002-shaped pool after 2 s. In the moving weld pool configurations, the sizes of the pools were maximum at the trailing electrodes. The pool was 1.7 mm deep and 5.6 mm wide in DC double- and 1.4 mm deep and 5.4 mm wide in PC double-electrode configurations. The pool depth and width were only 1.0 mm and 4.2 mm when a DC single-electrode setup was used. Comparing the three methods, the DC double-electrode setup produced the largest pool size. The findings of this research offer guidance for enhancing different arc settings and electrode arrangements to attain the intended welding quality and performance.

Publisher Name
J. Manuf. Mater. Process
more of publication
publications

Three different Gas Tungsten Arc Welding methods—DC single electrode, DC double electrode, and PC double electrode—were analyzed using SS304 steel as the base material. Numerical models were…

by Shahid Parvez
2026
Published in:
J. Manuf. Mater. Process
publications

Improving the thermal efficiency of Trombe walls is crucial for optimizing passive solar heating systems. Despite extensive research, the effect of ribbed surfaces on the thermo-hydrodynamic…

by Jamal-Eddine Salhi, Tarik Zarrouk, Supriya Jain, Mohamed Barboucha, Md Irfanul Haque Siddiqui, Shahid Parvez, Geleta Afessa Moreda
2026
Published in:
Scientific Reports
publications

Pure and indium-substituted cobalt ferrite nanoparticles with composition CoFe2−ₓInₓO4 (x = 0.00 and 0.5) were successfully synthesized via an environmentally friendly green tea-assisted…

by Prabin Kumar, Rashi Yadav, Nitish Kumar, Hemant Kumar, Neeraj Kumar, Shahid Parvez, Md. Muzzammilul Haque Siddiqui, Intesaaf Ashraf, Gulshad Nawaz Ahmad
2026
Published in:
Journal of Materials Science: Materials in Electronics