Skip to main content
User Image

Soilman A. Alhudaithy, Ph.D,

Assistant Professor

Assistant professor

Applied Medical Sciences
Building 24, 2nd floor, office 2252
publication
Journal Article
2025

Impact of Interdigital Electrode Count on Non-Faradaic Electrochemical Biosensor Performance for Detecting Pathogens Associated with Newborn Disabilities

Human cytomegalovirus can cause severe disabilities in newborns, including deafness, blindness, and developmental issues. Current detection methods are expensive, time-consuming, and require specialized training. Non-faradaic impedimetric biosensors offer a rapid, low-cost alternative by detecting pathogens directly without redox probes or three-electrode setups. This study investigates how the number of gold interdigitated electrodes (IDEs) on a polymeric substrate affects biosensor performance against UL83-antigens of human cytomegalovirus. Specifically, three sets of IDEs were tested: 8, 16, and 32 electrodes. First, the effect of the interdigital electrodes number on the impedimetric parameters of bare electrodes was investigated. Then the electrodes were biofunctionalized with UL83-antibodies to detect varying UL83-antigen concentrations. Following biofunctionalization, biosensing results show that increasing the number of electrodes enhances sensitivity (4.77 to 7.86 nF/ln(ng ml−1)) and lowers the detection limit (600 to 1.1 ng ml−1). This improvement is attributed to the increased surface area and stronger electric field with higher electrode counts. Additionally, biosensor selectivity and stability in detecting UL83 antigens were evaluated. Consequently, the biosensors demonstrated excellent selectivity and showed only slight performance decreases when tested over 3 days, and 1, 2, and 4 week periods. This study provides new insights into optimizing non-faradaic impedimetric biosensors for direct, redox-free pathogen detection.

Publisher Name
Journal of The Electrochemical Society
more of publication
publications

Wearable sensors have recently become essential tools in both preventive and corrective healthcare. Fused deposition modeling (FDM) is one of the rapidly evolving 3D-printing fields with…

by Ziyad Aloqalaa, Abdulsalam A. Al-Tamimi, Soliman A. Alhudaithy, Faisal S. Fakhouri, Omar Alageel, Abdulaziz S. Fakhouri
2026
Published in:
Journal of Materials Science: Materials in Electronics
publications

Laboratory safety is a critical component of biomedical engineering (BME) education due to the interdisciplinary nature
of the field and the associated chemical and electrical hazards. Despite…

by AHMAD O. ALOKAILY, SUHAIL S. ALSHAHRANI, AHMED A. ALDOHBEYB, SOLIMAN A. ALHUDAITHY, ABDULAZIZ S. FAKHOURI, MOHAMMAD K. ALSENAIDE, and ABDULELAH S. ALREBAISH
2026
Published in:
International Journal of Engineering Education
publications

Human cytomegalovirus can cause severe disabilities in newborns, including deafness, blindness, and developmental issues. Current detection methods are expensive, time-consuming, and require…

by Abdulaziz K. Assaifan, Rawan A. Almansour, Jana A. Alessa, Amir Altinawi and Soliman Alhudaithy
2025
Published in:
Journal of The Electrochemical Society