Skip to main content
User Image

حسن حامد كعبي Dr. Hassan H Kaabi

Associate Professor

أحياء الفم

Dentistry
كلية طب الأسنان, الدور الأول
publication
Journal Article
2026

Comparative Detection and Inter-Modality Agreement of Pulp Stones Using Digital Periapical Radiography and CBCT at Two Voxel Sizes: An Ex Vivo Study

Background/Objectives: Pulp stones are calcified masses within the dental pulp that may complicate endodontic procedures. Although cone beam computed tomography (CBCT) has been reported to detect pulp stones more frequently than two-dimensional radiography, direct comparisons between digital periapical radiography (DPR) and CBCT, particularly at different voxel sizes, remain limited. This study aimed to compare pulp stone detection rates between DPR and CBCT acquired at two voxel sizes and to evaluate inter-modality agreement using a location-based analysis for pulp stone identification in extracted teeth. Methods: Fifty-two extracted human teeth were examined using DPR and CBCT at voxel sizes of 0.2 mm and 0.1 mm under standardized ex vivo conditions. Pulp stones were evaluated in the coronal and radicular regions using a binary scoring system (presence/absence). Detection rates were compared across imaging modalities, and inter-modality agreement was evaluated using McNemar’s test in the analysis stratified by pulp stone location. Associations between pulp stone detection and age, gender, tooth status, and stone location were explored using chi-square tests. Results: CBCT at 0.1 mm demonstrated the highest detection rate for pulp stones (63.5%), followed by CBCT at 0.2 mm (57.7%) and DPR (50%), with no statistically significant differences among modalities (p > 0.05). Agreement analysis showed that CBCT at 0.2 mm had higher agreement with CBCT at 0.1 mm than DPR, particularly in the coronal region, whereas DPR showed lower agreement in the radicular region. No significant associations were observed between pulp stone detection and age, gender, or tooth status. Conclusions: Under standardized ex vivo conditions, CBCT showed numerically higher pulp stone detection rates than DPR. Location-based agreement analysis indicated greater consistency between CBCT voxel sizes than between CBCT and DPR, particularly in the radicular region. These findings highlight differences in pulp stone detectability across imaging modalities and voxel resolutions and may help explain variability in radiographic detection under controlled conditions.

more of publication
publications

Background/Objectives: Pulp stones are calcified masses within the dental pulp that may complicate endodontic procedures.

by Hassan Hamed Kaabi 1,*,† , Sarah Saeed Binhassan 2,† , Sultan Hamad Alrumaih 3 , Mohammed Jamal Alotaibi 3 , Abdullah Khalid Bakarman 3 , Nawaf Abdulaziz Alghamdi 3 , Hamad Abdullah Almuhaythif 3 , Qamar Mohammadziad Hashem 4 and Abdulfat
2026
publications

Effective guided bone regeneration (GBR) relies on barrier membranes that prevent soft tissue infiltration and create a protected environment conducive to osteogenesis. Current membranes,…

by Sara Gamea, Hassan Kaabi, Islam Elredah, Hanan Aljohani, Shwan Horamee, Hadeel J.N. Abu Shaqrah , Emily Ming-Chieh Lu, Tom Hodgkinson, Hanan Balto h , Paul T. Sharpe, Sherif Elsharkawy
2026
Published in:
Biomaterials Advances
publications

Objectives

The purpose of this study was to assess the effects of self-reported perception of facial and dental aesthetics on academic and social performance among…

by Aseel Sharaireh, Eman Hassuneh, Hiba Nasser, Nesreen Salem, Sanaa Aljamani, Hassan Kaabi, Faleh Sawair, Mohammad AL-Rabab’ah
2026
Published in:
International Journal of Dentistry