Skip to main content
User Image

Abdulaziz M Albaker

Associate Professor

Faculty

Dentistry
2B/28, college of Dentistry

Comparison of clinical and radiographic status around immediately loaded versus conventional loaded implants placed in patients with type 2 diabetes: 12- and 24-month follow-up results

Al-Kheraif, M. D. Al Amri, A. M. Alfarraj Aldosari, S. S. Al-Johany, A. M. Al Baker, M. Q. Al Rifaiy, A. A. . 2017

Summary: There are no studies that have compared the clinical and radiographic status around

immediately loaded (IL) and conventional loaded (CL) implants placed in patients with type 2

diabetes mellitus (T2DM). The aim was to compare the clinical and radiographic status around IL and

CL implants placed in T2DM patients. One hundred and eight diabetic patients [55 with IL implants

(Group 1) and 53 with CL implants (Group 2)] were included in this cross-sectional study. All implants

were placed in healed sites in the maxillary and mandibular premolar and molar regions and

supported single restorations. All patients underwent full mouth mechanical debridement

biannually. Haemoglobin A1c (HbA1c) levels, clinical [bleeding on probing (BOP) and probing

depth (PD) ≥ 4 mm] and radiographic [crestal bone loss (CBL)] peri-implant parameters were measured

for both groups at 12- and 24-month follow-up.Group comparisons were performed using the Mann–Whitney U-test (P < 005). The mean age and duration of T2DM in groups 1 and 2 were 506  22 and 518  17 years, and 92  24 and 85  04 years, respectively. At 12- and 24-month follow-up, the mean HbA1c levels in groups 1 and 2 were 54%

(48–55%) and 51% (47–54%) and 51% (47–52%) and 49% (45–52%), respectively. At 12- and 24-

month follow-up, there was no statistically significant difference in peri-implant BOP, PD and CBL in both groups. It was concluded that clinical and radiographic status is comparable around IL and CL implants placed in patients with T2DM.

The contribution of careful case selection, oral hygiene maintenance and glycaemic control is emphasised.

 

Volume Number
44
Magazine \ Newspaper
Journal of Oral Rehabilitation
Pages
220 - 228
more of publication
publications

Background: The aim of this study is to compare peri-implant soft tissue parameters (plaque index [PI], bleeding on probing [BOP], and probing depth [PD] ≥4 mm) and crestal bone loss (CBL) around…

by Al Amri MD, Kellesarian SV, Abduljabbar TS, Al Rifaiy MQ, Al Baker AM, Al-Kheraif AA.
2017
publications

Summary: There are no studies that have compared the clinical and radiographic status around

immediately loaded (IL) and conventional loaded (CL) implants placed in patients with type 2…

by M. D. Al Amri, A. M. Alfarraj Aldosari, S. S. Al-Johany, A. M. Al Baker, M. Q. Al Rifaiy, A. A. Al-Kheraif
2017
publications

Objective:The aim of the present 36-month prospective split-mouth clinical trial was to investigate the peri-implant soft tissue changes and crestal bone loss (CBL) around delayed loaded platform…

by Al Amri MD, Al-Johany SS, Al Baker AM, Al Rifaiy MQ, Abduljabbar TS, Al-Kheraif AA.
2016