تجاوز إلى المحتوى الرئيسي
User Image

Dr Ammar TIGHEZZA

Associate Professor

Faculty

كلية العلوم
2 A 146 Building 5
المنشورات
مقال فى مجلة
2022

Electrochemical Polymerisation of Glutamic Acid on the Surface of Graphene Paste Electrode for the Detection and Quantification of Rutin in Food and Medicinal Samples

voltammetry rutin graphene glutamic acid caffeine electrochemical analysis

Rutin (RU) is one of the best-known natural antioxidants with various physiological functions in the human body and other plant species. In this work, an efficient voltammetric sensor to detect RU in food samples was explicated using a poly (glutamic acid)-modified graphene paste electrode (PGAMGPE). In order to detect RU, the proposed sensor diminishes material resistance and overpotential while increasing kinetic rate, peak currents, and material conductance. Using differential pulse voltammetry (DPV) and cyclic voltammetry (CV), the analysing efficiency of a PGAMGPE and a Bare graphene paste electrode (BGPE) was evaluated in 0.2 M phosphate buffer (PB) at an ideal pH of 6.5. in a potential window of −0.25 V to 0.6 V. Electrochemical impedance spectroscopy (EIS) was used to analyse the prepared electrode materials’ conductivity, charge transfer resistance, and the kinetics of electron transport. Field emission scanning electron microscopy (FE-SEM) images were considered to compare the exterior morphology of the PGAMGPE and the BGPE. It was discovered that the PGAMGPE and the BGPE have electroactive surfaces of 0.062 cm2 and 0.04 cm2, respectively. It was determined that two protons and two electrons participated in the redox process. The resultant limit of detection (LOD) was found to be 0.04 µM and 0.06 µM, respectively, using DPV and CV methods. In spite of common interferents such as metal ions and chemical species, the developed sensor’s selectivity for RU detection was impressive. For the simultaneous analysis of RU in the presence of caffeine (CF), the PGAMGPE affords a good electrochemical nature for RU with good selectivity. Due to the good stability, repeatability, reproducibility, and ease of use of the present RU sensor, it is useful for real sample analysis such as food and medicinal samples with recovery ranging from 94 to 100%.

Graphical abstract

 

نوع عمل المنشور
Research
مزيد من المنشورات
publications

We investigate the structural, optoelectronic, and thermoelectric properties of halide double perovskite X2GeSnI6 (X = Rb, Cs) compounds employing the full potential linearized augmented plane…

بواسطة Malak Azmat Ali, M. Musa Saad H.‑E., Ammar M. Tighezza, Shaukat Khattak, Samah Al‑Qaisi, Muhammad Faizan
2023
publications

The research was done on the creation and use of bi-metal sulfide thin film, Nd2S3:Ni9S8. 41 nm-sized crystallites with 80% crystallinity were found in the material. The evaluated optical…

بواسطة Mahwash Mahar Gul, Khuram Shahzad Ahmad, Andrew Guy Thomas, Ammar Mohamed Tighezza
2023
publications

Perovskite solar cell (PSC) technology is extensively used in commercial sectors, but concerns about the use of lead and degradable components in cells are increasing.

بواسطة Farhana Bari Sumona, Muhammad Kashif, Eli Danladi, Ammar M. Tighezza, Nahid Al-Mahmud, Gazi F. I. Toki, Rahul Pandey, and M. Khalid Hossain
2023