Accuracy of Interchangeable Implant Impression Systems: An In Vitro Pilot Study

Anil, 1.Abdullah M. AlFarraj Aldosari, 2. Abdulaziz M. AlBaker, 3. Abdulmonem A. AlShihri, 4. Majid I. AlJadeed, 5. Loay A. AlBwardi, 6. Sukumaran . 2015

Purpose:To evaluate the accuracy of impressions on changing the implant component (coping and abutment replica) between Brånemark and BIOMET 3i and between Straumann and Allfit.

Materials and Methods:Two master casts were constructed, one containing pair of Brånemark self-tap Mk II fixtures (Nobel Biocare) labeled Master cast I and the other containing pair of Straumann Standard plus implant, SLA fixtures (Straumann) labeled Master cast II. Ten impressions of each master cast were made by open tray technique using polyether impression material. Five out of 10 impressions made from master cast I contained Brånemark pair of coping and replica and the other 5 contained 3i (Implant Innovations). Five out of 10 impressions made from master cast II contained Straumann pair of copings and replica and the remaining 5 contained Allfit implants (Ihde Dental). Duplicated casts were prepared, and distances between copings were measured using traveling microscope and compared the distance in master casts.

Result: No significant difference was observed in mean value between 2 master casts and their duplicates.

Conclusion:The interchangeability of coping and abutment replica between Brånemark and BIOMET 3i and between Straumann and Allfit was found to be possible without compromising the quality of impressions.

رقم المجلد
24
رقم الانشاء
2
مجلة/صحيفة
Implant Dentistry
الصفحات
1 - 6
مزيد من المنشورات
publications

Background: The aim of this study is to compare peri-implant soft tissue parameters (plaque index [PI], bleeding on probing [BOP], and probing depth [PD] ≥4 mm) and crestal bone loss (CBL) around…

بواسطة Al Amri MD, Kellesarian SV, Abduljabbar TS, Al Rifaiy MQ, Al Baker AM, Al-Kheraif AA.
2017
publications

Summary: There are no studies that have compared the clinical and radiographic status around

immediately loaded (IL) and conventional loaded (CL) implants placed in patients with type 2…

بواسطة M. D. Al Amri, A. M. Alfarraj Aldosari, S. S. Al-Johany, A. M. Al Baker, M. Q. Al Rifaiy, A. A. Al-Kheraif
2017
publications

Objective:The aim of the present 36-month prospective split-mouth clinical trial was to investigate the peri-implant soft tissue changes and crestal bone loss (CBL) around delayed loaded platform…

بواسطة Al Amri MD, Al-Johany SS, Al Baker AM, Al Rifaiy MQ, Abduljabbar TS, Al-Kheraif AA.
2016