تجاوز إلى المحتوى الرئيسي
User Image

Dr. Haya Al Farhan

أستاذ مشارك

Associate Professor

كلية العلوم الطبية التطبيقية
225
المنشورات
مقال فى مجلة
2014

Normal corneal endothelial morphology of healthy Saudi children aged 7–12 years.

Masoud, Haya Al-Farhan, Waad Albalawi, Wagiha . 2014

article

Purpose
The aim of this study was to describe the corneal endothelial morphology of healthy Saudi
children aged 7–12 years and investigate variations on the basis of age and sex.
Participants and methods
In this prospective study of 412 healthy children, one eye was examined of each child. The
endothelial cell density ( ECD), percentage coeffi cient of variation (CV), and cell hexagonality
( Hex) were determined using a noncontact Nidek CEM 530 specular microscope. An unpaired
t-test was used to compare ECD measurements between boys and girls. Descriptive statistics
of endothelial characteristics (ECD, CV, Hex) of the right eyes of the children at each age
were analyzed for the entire sample using Kruskal–Wallis and Spearman’s correlation tests.
Results
The Kruskal–Wallis test showed statistically signifi cant differences in ECD on the basis of age
(P = 0.01) and Spearman’s correlation test detected a weak negative correlation between ECD
and age (−0.20, P = 0.0001). Analysis of the CV did not indicate any statistically signifi cant
differences with age (P = 0.98), but a weak positive correlation was detected between CV and
age (r = 0.02, P = 0.69). No signifi cant differences in Hex were observed at each age (P = 0.10),
but a weak negative correlation was detected between Hex and age (r = −0.14, P = 0.001).
Conclusion
In children, ECD decreases with increasing age whereas CV and Hex do not change signifi cantly
with age.
Keywords:
cell hexagonality, endothelial cell density, Nidek CEM 530 specular microscope, noncontact

نوع عمل المنشور
article
رقم المجلد
107
مجلة/صحيفة
The journal of Egyptian ophthalmology
الصفحات
63-66
مزيد من المنشورات
publications

Abstract

Purpose: To develop a Fourier method to assess wrinkling and other regular structure on the posterior capsule following cataract surgery

بواسطة C.C. Hull; H.M. Al–Farhan; R. Hameed; S.E. Horgan
2004
publications

Purpose:  Posterior capsular opacification (PCO) is the commonest complication of cataract surgery. The aim of this work is to develop a system that could be used by primary care practitioners to…

بواسطة H. Al-Farhan1, C. C. Hull1, R. Hameed2, S. E. Horgan2 and E. G. Woodward1
2002
publications

Purpose: To compare the precision of central corneal thickness (CCT) measurements taken with the handheld ultrasound pachymeter (USP), ultrasound biomicroscopy (UBM), and the Artemis-2 very high…

بواسطة Al-Farhan HM1, Al-Otaibi WM.
2012