King Saud University
  Help (new window)
Go Search
تحميل الدليل التدريبي

أسئلة شائعة


 
a) Publications in Refereed Journals (Papers before 1990 are not included)

Title

Journal

Date
Pages

Effect of the embedding technique in fibre optic-based force sensor for dentistry: Nano-strain analysis.

Technisches Messen, Geramny, Vol. 76

7-8/09

378-381

Effect of splinting in a fixed partial denture on bone response: FEM study

Egyptian Dental Journal, Cairo, 55(3)

7/09

1999-2005

Smooth versus threaded-neck dental implant designs using finite element analysis

Egyptian Dental Journal, Cairo, 54(2)

4/08

1353 - 1360

Investigating the prospective use of fibre optics based sensors in dentistry

Technisches Messen, Germany, Vol. 75

3/08

207 - 211

Evaluation of the effect of abutment splinting in tooth-implant supported fixed restorations

Cairo Dental Journal, 20(3) part II

9/04

535 – 538

Evaluation of implant site on the stresses transmitted under distal extension implant supported removable partial denture.

Cairo Dental Journal, 20(3) part II

9/04

499 – 502

Effect of abutment type on stresses transmitted to supporting structures in implant supported partial dentures. A stress analysis study

Egyptian Dental Journal, Cairo University, 50(3)

07/04

1593 – 1601

Management of terminal questionable abutment in Kennedy Class-II cases- A stress analysis study

Egyptian Dental Journal, Cairo University, 50(1)

01/04

5 – 10

Biomechanical analysis of prosthesis designs used in Treatment of tilted molar

Engineering Research Bulletin, Helwan Univ.

12/01

119 – 131

Stresses around two bio-ceramic implants used as abutments for partial denture

Journal of Engineering & Applied  Science

08/01

793 – 806

Stress Analysis of different prosthodontic restorations with tilted posterior abutments

Egyptian Dental Journal, Cairo University

10/98

3309– 3317

Effects of Splinting on load distribution of extracoronal attachments with distal extension prosthesis in-vitro

Journal Prosthetic Dentistry, St Louis, Mo., USA

9/96

315 – 320

Load distribution in osseointegrated implant supporting extended and non-extended dentures

Egyptian Dental Journal, Cairo University

10/95

1347– 1356

Measurement of cutting force in turning using simple dynamometer

Engineering Research Bulletin, Helwan Univ.

6/94

107 – 130

Measurement of  load distribution on dental implants supporting a bridge

Engineering Research Bulletin, Helwan Univ.

8/93

97 – 110

Stress Analysis of a new modified osseointegrated implant for distal extension prosthesis

Al-Azhar Dental Journal, Al-Azhar University

5/92

335 – 346

Stress Analysis of two osseointegrated implants for distal extension prosthesis

Al-Azhar Dental Journal, Al-Azhar University

5/92

347 – 362

Modifications of Osseointegrated implant for distal extension prosthesis

Journal Prosth. Dentistry, St Louis, Mo., USA

10/90

469 – 472

 

b) Publications in Refereed Conferences (Papers before 1988 are not included)

Title

Conference name & Place
Organizer
Date

A dual fibre optic sensor for ambiguity measurement of electrical strain gauges transient heating effect and apparent strain

5th Int. Conf. on Intillegent sensors, sensors neworks & information processing, Melbourne, Australia, 7-10, Dec. 2009

ARC Resarch network on Intillegent sensors, sensors neworks & information processing,

 

Effect of splinting in a fixed partial denture on bone remodeling using FEM

4th Europ Cong for Med & Biomed Eng 08 "Eng for Health", Antwerp, Belgium

Belgian Society for med & biolog eng & comput

23–27 Nov, 08

Effect of embedding type of fiber optic-based force sensor for dentistry: Nano-strain analysis

International Conference on Precision Measurement

Technische Univ., Ilmenau, Germany

08 – 12 Sep. 08

Smooth versus threaded-neck dental implant designs using finite element analysis

12th Saudi International Dental Meeting – Integrating Science into Dental Pratice,

KSU, Faculty of Dentistry

12 – 14 April, 08

Evaluation of stresses and displacement in different clasp-retained partial dentures: In-vitro study

12th Saudi International Dental Meeting – Integrating Science into Dental Pratice,

KSU, Faculty of Dentistry

12 – 14 April, 08

Prediction of the optimum number of teeth supporting a long fixed partial denture: A finite element model study

12th International Conference of Machine design and production

(UMTIK2006) Kusadasi, Turkey

9/06

Comparison of the permanent deformation of two clasp designs under the simulated action of insertion and removal

1st Inter Implantology Conference, Cairo, Egypt

Biomedical Eng. Department, Cairo university

12/02

Stresses Induced in Abutment Teeth due to Long Span Bridge: A Case Study

4th Inter Implantology Conf, Cairo, Egypt

Egypt. Scientific Society, Dental Implantology

4/01

In-vitro model to evaluate the effect of attachment designs on stresses transferred to the surroundings in implant-retained overdentures

7th. Inter Conference on Mech. Design and Production, Cairo, Egypt

Faculty of Engineering Cairo University

2/00

Development of a multidirectional transducer to measure loading on dental implants

3rd Inter Conf. Faculty of Engineering, Cairo, Egypt

Faculty of Eng. Al-Azhar Univ.

12/93

Biomechanics of dental implants with and without intra-mobile element: Computer Modeling

17th Annual meeting, Am. Assoc. Dent. Res. , Canada

American Assoc. Dental Research

3/88

 

 

 

 

c) Notes & Reference Books

Title

Authors

Dates

Publisher/University

AutoCAD (Elementary)

Single

97,03

Cairo, American Univ. (notes)

Engineering Economy

Single

90-92

Helwan University (notes)

 

d) Thesis Supervision
No

Title

Degree

University

Dates

1

Comparing different retainers of various asymmetric distal extension removable partial dentures

M.Sc.

Faculty of Dentistry, Ain Shams Univ.

1/04 – 9/08

2

Evaluation of implant diameter effect on stress transmission under mandibular overdentures

Ph.D.

Faculty of Oral and Dental Medicine, Cairo University

2002 – 2005

3

Stress analysis induced by distal extension prosthesis with extended extra-coronal attachment

M.Sc.

2002 – 2006

4

Evaluation of implant site on the stresses transmitted under distal extension implant supported removable partial denture

M.Sc.

2001 – 2004

5

Evaluation of sectional partial denture for upper posterior bounded saddle

M.Sc.

Faculty of dent., Tanta Univ.

2001 – 2004

6

Load distribution with different superstructure designs of osseointegrated implants

Ph.D.

Faculty of Oral and Dental Medicine, Cairo University

6/89 – 5/93

7

Stress analysis study of a modified endosseous implant for distal extension prosthesis

M.Sc.

4/90 - 8/91

8

Effect of Splinting on load distribution with extra-coronal attachments in mandibular distal extension removable partial denture

M.Sc.

4/93 – 11/94

9

The relation between two types of clasps and their liability for permanent deformation

M.Sc.

5/93 – 10/94

10

Stress analysis of bar-connected copings vs. conventional copings in complete dentures

M.Sc.

3/94 – 5/97

11

Stresses transmitted  to the principal abutment in unilateral distal extension base partial denture

M.Sc.

2/96 – 9/97

 

e) Refereeing engineering articles and thesis in KSA

 

1.  KACST proposal review "Signal processing for cardiac mapping" May-June 2009.

2.  M.Sc. King Abdel Aziz Univ. "fracture behavior of poly_methyl_acryl", 3/6/1428 (18/6/2007)

3.  The Effect of Muscle Fatigue on Knee Flexor to extensor torque ratios and knee dynamic stability”, Arabian Journal for Science and Engineering, King Fahd University of Petroleum & Minerals April 10, 2006.

4.  Evaluation of Saudi school furniture available in the local market: biomechanical and psychological based study”, The 12th International Conference on Machine Design and Production, 05 - 08 September 2006, Kuşadası, Turkey March 2006.

5.  Some properties of dynamically vulcanized EPDM/polypropylene thermoplastic” Journal of King Abdul-Aziz Univ. Jan 2005.

6.  Industrial noise and its effect on workers in Palestinians industrial plants” Journal of King Abdul-Aziz Univ. May, 2004

 
King   Saud University. All rights reserved, 2007 | Disclaimer | CiteSeerx